Growatt ES Series Inverter Pin Layout & Cloudlink

Modified on Wed, 28 Aug at 3:38 PM

PIN LAYOUTS & CLOUDLINK

 

Hubble Energy recommends the Cloudlink Device on Growatt installations. It is not required but recommended.

 

CLOUDLINK

The Cloudlink will connect to the Battery via:

Cloudlink’s (Serial/RJ12 Port) to the Battery (RS232/RJ12 Port)

(Black Cable) – RJ12 to RJ12 (450mm) cable.

 

 

RJ45 PIN LAYOUTS

The Growatt Inverter will connect to the Battery via:

Inverter (CAN Port) to Battery (CAN Port)

Straight RJ45 to RJ45 wire - 1500mm. 

Ensure that the clip is pointed away from you when counting the pins.

 

Pin

Inverter

X-101/AM-4/AM-2

AM-5/AM-10

Blade

1

-

-

-

-

2

-

-

-

-

3

-

-

-

-

4

CANH

CANH

CANH

CANH

5

CANL

CANL

CANL

CANL

6

GROUND

GROUND

-

-

7

-

-

-

-

8

-

-

-

-

 

FINAL STEP TO GROWATT SPF 5000 ES SERIES INVERTER:

To connect battery BMS, need to set the battery type as “LI” in Program 05.
 After set “LI” in Program 05, it will switch to Program 36 to choose communication protocol. You can choose RS485 communication protocol, which is from L01 to L50, and you can also choose CAN communication protocol which is from L51 to L99.

 

 

4 & 5 Pin Layout image reference seen below:

 

 






















4, 5 & 6 Pin Layout image reference seen below:

 