Axpert Type Inverters Pin Layouts & Cloudlink

Modified on Wed, 28 Aug at 3:35 PM

PLEASE NOTE

 

Axpert type inverters require a Cloudlink to access full CAN-BUS communication with a Hubble Energy battery, it is however not required, and the system will be functional on user defined voltage control.

 

CLOUDLINK

 

The Cloudlink will connect to an Axpert type Inverter via:

Cloudlink’s (Serial/RJ12 Port) to the Axpert type Inverter (RS232 Port) 

(Black Cable) - RJ12 to RJ45 (450mm) cable.

 

The Cloudlink will connect to the Battery via:

Cloudlink’s (CAN Port) to the Battery (CAN Port) 

(Blue Cable) - Standard RJ45 to RJ45 (1500mm) cable.

 

RJ45 PIN LAYOUTS

Ensure that the clip is pointed away from you when counting the pins.

 

Pin

X-101/AM-4/AM-2

AM-5/AM-10

1

-

-

2

GROUND

-

3

-

-

4

CANH

CANH

5

CANL

CANL

6

 

-

7

-

-

8

-

-


 

2, 4 & 5 Pin Layout image reference seen below:                                                                                          (Blue Cable)

 























4 & 5 Pin Layout image reference seen below:                                                                      (Blue Cable - Modified)

A close-up of a cable